Industrial filter cartridge
>Home >All products >SE-shield>filters/cartridges >industrial
         
 


 

Used against particles, dust, smoke, fume, bacteria, viruses, biological warfare agents, and a wide range of organic, inorganic and acid gases and ammonia.

Examples: industrial gases such as ammonia, hydrogen cyanide, acid gases, chlorine, sulfur dioxide, hydrogen chloride and many more.

Also provides protection against Sarin, nerve gas, mustard gas, cyanogen, phosgene, radioactive dust, toxic particles, aerosols, tear gas, bacteria, viruses, anthrax, smallpox etc.

 

 

Description:
Industrial filter, available in two weights
Product name:
SE400 industrial filter
Use:

Used against particles, dust, smoke, fume, bacteria, viruses, biological warfare agents, and a wide range of organic, inorganic and acid gases and ammonia.

Examples:  industrial gases such as ammonia, hydrogen cyanide, acid gases, chlorine, sulfur dioxide, hydrogen chloride and many more.

Also provides protection against Sarin, nerve gas, mustard gas, cyanogen, phosgene, radioactive dust, toxic particles, aerosols, tear gas, bacteria, viruses, anthrax, smallpox etc.

Material:
Reinforced polyamide. No metal parts.
Weight:
Large filter: 370g (12.95 oz)
Small filter: 320g (11.2 oz)
Thread:

NATO/EN 148-1.40mm

Diameter:

109 mm (4.3")

Capacity:
Industrial compounds:      
Compound Conc. (ppm) Flow rate (1/min) Filter capacity (min)
Cyclohexane C6H12 5000 30 50
Chlorine C12 5000 30 40
Hydrogen sulfide H2S 5000 30 >120
Sulfur dioxide SO2 5000 30 23
Ammonia NH3 5000 30 50
Carbon tetrachloride CC14 1000 64 >65
Methylomine CH3NH2 1000 64 >80
Hydrogen chloride HC1 500 64 >35
C1O2 500 64 >60
Hydrogen fluoride HF 70 64 >60
Formaldehyde HCHO 100 64 >100
O-chlorobenzylidene
malonotrile CS
3 64 >480
CN teargas 16 64 >480
DOP 200mg 85 40mm H20 (penetr.0.004%)
NaCl   95 0.001%

 

 

Warfare compounds*:      
Compound Conc. (ppm) Flow rate (1/min) Filter capacity (min)

Sarin GB (Tested by SBCCOM)

Nerve agent
Lethal dose: 35 mg/m3
Effectice dose: 25 mg/m3

300 mg/m3 25 >60

Hydrogen cyanide HCN

Blood agent
Lethal dose:
varies widely with concentration

5000 30 72

Cyanogen chloride CK
(Tested by SBCCOM)

Blood agent
Lethal dose: 11,000 mg/m3
Effective dose: 7,000 mg/m3

4000 mg/m3 50 >45

O-chlorobenzylidene malonotrile CS

Tear gas
Lethal dose: 61,000 mg/m3
Effective dose: 10-20 mg/m3

3 64 >480

Chloroacetophenone CN

Tear gas:
Lethal dose: 7,000-14,000 mg/m3
Effective dose: 80 mg/m3

16 64 >480

NOTE: Blue area signifies European test data using large filters. Remaining tests conducted in USA on small filters.

*) Warfare gas test results are not derived from, nor have any relation to NIOSH testing

Breathing resistance :
At 30 l/min: <1.2 mbar
At 95 l/min: <4.0 mbar
Storage period :

5 years if seal is unbroken.

Storage: Store at room temperature in clean, dry place

 



Copyright © 2007 by The S.E.A. Group — all rights reserved