| Description: |
Manifold/regulator for air-line respirators. |
| Use: |
Delivers airline pressure for up to three positive pressure demand respirators simultaneously. |
| Product name: |
S.E.A. Supplied-Air Manifold |
| Wall-mounted configuration: |
With wall mounting bracket (accessory) and flexible high pressure hoses to suit two G-size cylinders |
| Hand-held configuration: |
With carry handle (optional accessory) to suit single cylinder only (except G-size) |
| SpiroCART configuration: |
Mounted on two-wheeled trolley to suit two cylinders in a range of sizes. Optional hose reel with 25 metres of 0.5 mm rubber airline. |
| Pressure gauges: |
- High-pressure gauge (standard)
- Airline pressure gauge (optional)
|
| Low pressure warning whistle: |
Activates at 54–60 bar (hand-held/SpiroCART versions) or 10–20 bar (wall-mounted version only) |
| Air supply: |
One or two cylinders
Supply pressure: 300 bar (hand-held/SpiroCART) or 163 bar (G-size cylinders) |
| Approved cylinder types: |
- BOC 300 bar 4 litre composite
- EFIC 300 bar 6.8 litre composite
- Spiromatic 300 bar 4 litre steel
- Spiromatic 300 bar 6 litre steel
- G-size (wall-mounted version only)
|
| Cylinder changing: |
The manifold continues to deliver breathing air from one cylinder while the other cylinder is being changed |
| Air outlets: |
Two CEJN airline connectors standard. Third outlet optional. |
| Outlet pressure: |
7–10.5 bar |
| Weight: |
2.1 kg |
| Dimensions: |
- Height: 330 mm
- Width: 170 mm
- Depth: 140 mm
|