DATA SHEET Sundström SR295 gas filter K2 for Sundström full face masks |
![]() |
|
Updated: 17 Jan 2005 |
||
Description: |
Ammonia filter class K2 |
|
Product name: |
SR295 |
|
Use: |
Used against ammonia vapour |
|
Material: |
Plastic polypropylene. No metal parts |
|
Weight: |
235 g (8.3 oz) |
|
Dimensions: |
Largest diameter: 106 mm (4.2") |
|
Carbon: |
The filter contains 166 g (5.9 oz) activated carbon |
|
Capacity: |
In tests with 5,000 ppm ammonia at 30 l/min, the filter lasts for 48-52 minutes (standards requirement: >40 min) | |
Pressure drop: |
30 l/min: 100 Pa (standards requrement: <140 Pa) 95 l/min: 380-400 Pa (standards requirement: <560 Pa) |
|
| Particle filter: | If environment contains both particles and gas, a particle filter must be fitted to the front of the gas filter | |
| Pre-filter: | Pre-filter 221 and pre-filter holder 5153 should always be fitted | |
| Storage period: | 3 years if seal is unbroken. Expiry date printed on the filter | |
| Storage: | Store at room temperature in clean, dry place | |