DATA SHEET Sundström SR76-2 escape hood
|
![]() |
||||||||||||||||||||||||||||||||||
Updated: 11 April 2005 |
|||||||||||||||||||||||||||||||||||
Description: |
The SR 76-2 Escape Hood is a filtering respiratory protective device combined with a hood. |
||||||||||||||||||||||||||||||||||
Usage: |
Used in accidents involving chemicals. |
||||||||||||||||||||||||||||||||||
Product name: |
SR 76-2 S, S/M (Stationary Storage) SR 76-2 M, S/M (Portable escape hood) SR 76-2 S, M/L (Stationary Storage) SR 76-2 M, M/L (Portable escape hood) |
||||||||||||||||||||||||||||||||||
Face piece: |
Available in Small/Medium and Medium/Large sizes and fits most adults and teenagers. |
||||||||||||||||||||||||||||||||||
Hood: |
The hood is based on a Sundstrom silicone half mask, which is mounted in a hood made of chemicals-resistant material. |
||||||||||||||||||||||||||||||||||
Visor: |
Scratch-resistant, anti-mist, polycarbonate |
||||||||||||||||||||||||||||||||||
Fitting: |
The hood can be put on quickly and simply, without prior adjustment. | ||||||||||||||||||||||||||||||||||
Temperature: |
-30°C to +70°C (-22F to +158F) |
||||||||||||||||||||||||||||||||||
Filter: |
The hood is equipped with combined filter SR 299-2, ABEK1-Hg-P3 and provides protection against all types of particles and following gas types: A1 organic gases and vapours, such as solvents, with boiling points above 65oC. |
||||||||||||||||||||||||||||||||||
Weight: |
490 g |
||||||||||||||||||||||||||||||||||
Size of pack: |
120 x 120 x 170 mm (4.7" x 4.7" x 6.7 ") |
||||||||||||||||||||||||||||||||||
Storage: |
The hoods are vacuum-packed in aluminium bags. The SR 76-2 M is delivered in a contingency bag made of nylon and designed for mounting on a belt. |
||||||||||||||||||||||||||||||||||
Shelf life: |
Hood: 15 years if inner bag is unbroken. Filter: 7.5 years if inner bag is unbroken. Respirator should be returned after 7.5 years for filter replacement and re-sealing of bag. It can then be kept for another 7.5 years. |
||||||||||||||||||||||||||||||||||
Gas/particle resistance times: |
|
||||||||||||||||||||||||||||||||||
| Source: Product leaflet, Sundström Safety, PO5H-2218 Utg 03 0208 COI, 21 Mar 2003 | |||||||||||||||||||||||||||||||||||