DATA SHEET
SE-shield
CBRN protective suit for SE400
|
|
Updated: 10 Feb 2010 |
Description: |
Chemically impermeable protective suit, specially made for use with SE400 positive pressure demand respirator. Disposable, single-use suit. The SE400 is fitted with a pressurisation hose which maintains a slight positive pressure inside the suit. |
Product name: |
SE-shield |
Use: |
Used to protect the entire body while wearing the SE400 respirator. Protects against particles and gases. Protects against chemical and biological materials including CBRN warfare agents.
|
Material: |
Military grade Tychem F® material |
Weight of material: |
509 g/m2 |
| Suit construction : |
- Seams:
- Lap welded for extra strength .
- Visor seal:
- Fits tightly around the rim of the full face mask.
- SE400 hose:
- A hose sleeve fits around the entire length of the hose.
- SE400 filters:
- Sealed off from the interior of the suit by two threaded sealing rings.
- Gloves:
- Chemically impermeable gloves are fastened to the rigid sleeve rings with an airtight seal. The gloves are designed to be worn inside regular working gloves or rubber, leather or other materials.
NOTE: The supplied gloves are impermeable and impregnable, but are not designed for mechanical wear and tear. Heavy-duty outer gloves of butyl rubber, leather or similar must be worn over the inner gloves.
- Booties:
- Booties are permanently welded to the suit legs. The booties slip easily into regular outer heavy-duty boots or shoes. A special skirt covers the bootleg for further protection.
- SE400:
- The SE400 fan unit is worn on a balanced, convenient back-pack inside the suit.
|
| Fabric characteristics : |
- Burst resistance:
- 227 kPa
- Puncture resistance:
- 30.9 N
- Flex crack resistance:
- 2500 cycles
- Air permeability:
- Impermeable
- Water vapour permeability:
- Impermeable
- Exposure to high temperature:
- Seams open at +98°C (208.4F)
- Exposure to low temperature:
- Flexibility down to -70°C (-94F)
|
| Chemical breakthrough times : |
(Tested in accordance with ASTM F739-1991)
| Compound |
Breakthrough time (min) |
| Acetone |
>480 |
| Ammonia |
79 |
| Carbon disulfide |
>480 |
| Chlorine |
>480 |
| Dichloromenthane |
5 |
| Diethylamine |
>480 |
| Ethyl acetate |
>480 |
| Ethylene glycol |
>480 |
| Ethylene oxide |
65 |
| Hexane |
>480 |
| Hydrogen chloride |
>480 |
| Methanol |
77 |
| Methyl chloride |
>480 |
| Monoethanolamine |
>480 |
| NaOH cncentrate |
>480 |
| Sulfuric acid |
>480 |
| Tetrachloroethylene |
>480 |
| Toluene |
>480 |
| Xylene |
>480 |
| Mustard gas |
>480@+37° C(98.6F)* |
| Lewisite/Mustard (2:1) |
>480@+37° C(98.6F)* |
| VX |
>480@+37° C(98.6F)* |
*)Tested by TNO, the Netherlands |
| Inward leakage: |
| One unique feature of the SE-SHIELD suit is that it can be used with a pressurisation hose which turns the suit into a positive pressure suit. Inward leakage into the suit if using pressurisation hose is typically 0.1% |
 |
|
| Storage period: |